Search by compound, strength, lot, or report number. Match the report lot to the vial label before relying on a result. Reports describe the submitted sample and their stated test scope.

9 reports

Batch documentation

BAC Water 30 ml

Lot / batch
EB61901
Laboratory
Chromate
Report
35348 / EBAC444D2MUF
Report date
May 22, 2026 (analysis)
BAC Water 30 ml report results
AnalyteBenzyl alcohol
Reported concentration0.921% (specification: 0.9%)
Reported endotoxinsLess than 0.25 EU/mL
Reported pH6.253

Results transcribed from the attached report. See the original document for methods, specifications and all results.

Open original report PDF ↗ (opens in a new tab)

Batch documentation

GLOW 70 mg

Lot / batch
T-GLO-0029
Laboratory
Axiom Analytics Laboratories
Report
AX-2026-1783-2D9J
Report date
October 1, 2026
GLOW 70 mg report results
Reported component purityGHK-Cu: 99.63%; BPC-157: 99.64%; TB-500: 99.93%
Measured sample contentGHK-Cu: 52.55 mg; BPC-157: 10.51 mg; TB-500: 10.52 mg (73.58 mg total)
Sample count1 client-submitted vial
Microbial DNA screenTarget DNA not detected (rapid PCR)
Targeted fentanyl screenNot detected at the stated 1 ng/mg limit

Results apply to the submitted sample. The rapid PCR screen is not a batch sterility determination. See the original report for methods, limits and full results.

Open original report PDF ↗ (opens in a new tab)

Batch documentation

Glutathione 500 mg

Lot / batch
DPS-1818605
Laboratory
Horizon Analytical
Report
1018082
Report date
July 28, 2026
Glutathione 500 mg report results
Reported purity99.56%
Measured sample content512 mg
Report clientDirect Peptides

Supplier-linked report. Results apply to the submitted sample; match the report lot to your vial label.

Open original report PDF ↗ (opens in a new tab)

Batch documentation

KLOW 80 mg

Lot / batch
T-KLO-0030
Laboratory
Axiom Analytics Laboratories
Report
AX-2026-4306-9H9U
Report date
October 1, 2026
KLOW 80 mg report results
Reported component purityGHK-Cu: 99.40%; BPC-157: 99.92%; TB-500: 99.97%; KPV: 99.48%
Measured sample contentGHK-Cu: 53.23 mg; BPC-157: 10.45 mg; TB-500: 10.35 mg; KPV: 10.24 mg (84.27 mg total)
Sample count1 client-submitted vial
Microbial DNA screenTarget DNA not detected (rapid PCR)
Targeted fentanyl screenNot detected at the stated 1 ng/mg limit

Results apply to the submitted sample. The rapid PCR screen is not a batch sterility determination. See the original report for methods, limits and full results.

Open original report PDF ↗ (opens in a new tab)

Batch documentation

MOTS-C 40 mg

Lot / batch
T-MOT-0063
Laboratory
Axiom Analytics Laboratories
Report
AX-2026-3888-8KRU
Report date
October 1, 2026
MOTS-C 40 mg report results
Reported purity99.88%
Measured sample content42.15 mg
Sample count1 client-submitted vial
Microbial DNA screenTarget DNA not detected (rapid PCR)
Targeted fentanyl screenNot detected at the stated 1 ng/mg limit

Results apply to the submitted sample. The rapid PCR screen is not a batch sterility determination. See the original report for methods, limits and full results.

Open original report PDF ↗ (opens in a new tab)

Batch documentation

NAD+ 1000 mg

Lot / batch
T-NAD-0068
Laboratory
Axiom Analytics Laboratories
Report
AX-2026-3456-2CAJ
Report date
October 1, 2026
NAD+ 1000 mg report results
Reported purity99.72%
Measured sample content1069.22 mg
Sample count1 client-submitted vial
Microbial DNA screenTarget DNA not detected (rapid PCR)
Targeted fentanyl screenNot detected at the stated 1 ng/mg limit

Results apply to the submitted sample. The rapid PCR screen is not a batch sterility determination. See the original report for methods, limits and full results.

Open original report PDF ↗ (opens in a new tab)

Batch documentation

Selank 10 mg

Lot / batch
TP260630
Laboratory
Accumark Labs
Report
BFM9-T3F6
Report date
July 29, 2026
Selank 10 mg report results
Reported purity99.917%
Declared sample size10.0 mg
Measured sample content13.47 mg
Report clientResearch Vault

Supplier-linked report. Results apply to the submitted sample; match the report lot to your vial label.

Open original report PDF ↗ (opens in a new tab)

Batch documentation

Semax 10 mg

Lot / batch
TP260630
Laboratory
Accumark Labs
Report
3MP7-LAMC
Report date
July 30, 2026
Semax 10 mg report results
Reported purity99.697%
Declared sample size10.0 mg
Measured sample content6.29 mg
Report clientResearch Vault

Report note: Content discrepancy: this COA lists 10 mg declared content and 6.29 mg measured in the submitted sample. This result does not establish the content of every vial; confirm the applicable lot with the supplier and laboratory.

Supplier-linked report. Results apply to the submitted sample; match the report lot to your vial label.

Open original report PDF ↗ (opens in a new tab)

Batch documentation

SS-31 10 mg

Lot / batch
T-SS3-0016
Laboratory
Axiom Analytics Laboratories
Report
AX-2026-3357-YX3D
Report date
October 1, 2026
SS-31 10 mg report results
Reported purity99.88%
Measured sample content10.51 mg
Sample count1 client-submitted vial
Microbial DNA screenTarget DNA not detected (rapid PCR)
Targeted fentanyl screenNot detected at the stated 1 ng/mg limit

Results apply to the submitted sample. The rapid PCR screen is not a batch sterility determination. See the original report for methods, limits and full results.

Open original report PDF ↗ (opens in a new tab)